153
CA854
3.0L Single Point Drain
CAUTION
Ensure bilge pump is operating before beginning procedures.
Excess water in bilge can damage engine or cause boat to
sink.
CAUTION
Allow engine to cool down before disconnecting blue drain
hoses. Engine water temperature can exceed 160° F ( 71° C).
CAUTION
Do not operate engine with blue drain hoses disconnected.
Hot water can discharge violently.
IMPORTANT: Do NOT start or operate engine at any point in this
procedure.
1 Turn on bilge pump.
2 Push quick connect fitting release buttons (A) and remove blue
drain hoses (B) from the bracket.
3 Pull T-handle (A) until the hose guide (B) is in contact with the
quick connect fittings.
4 Push down on T-handle to force the blue drain hoses below their
connection points to the block (A).
5 Ensure water is draining from both blue drain hoses. If water is not
draining from one or both blue drain hoses, go to Clearing Clogged
Blue Drain Hoses”
6 Leave blue drain hoses disconnected until all water has drained
from engine.
7 Pull T-handle until the quick connect fittings (A) on the blue drain
hoses are within reach.
8 Install quick connect fittings on the bracket. Pull on the blue drain
hoses to ensure they are firmly connected.
9 Push down on handle and move into the slot on the bracket.
10Turn off bilge pump.
IMPORTANT: The next time the engine is started, visually
inspect that the blue drain hoses are connected and not leaking.