- 3 -
Serial Number Decal Location
A serial number decal is located on the side of the fly-
wheel cover and on top of the cylinder block.
19XX
XX
OGXXXXXX
OGXXXXXX
b
c
d
a
28238
a - Engine Serial Number
b - Model Year
c - Year Manufactured
d - Certified Europe
IMPORTANT: The Pump Unit Serial Number
sticker must be taken out of the envelope affixed
to the pump unit and applied to the flywheel cover
decal.
The engine serial number and pump serial number
are different and unique. The engine serial number is
located aft of the flywheel cover. The pump unit serial
number is stamped in a plug located above the shift
cable hole on the starboard side of the pump housing.
e
175
28237
e - Pump Unit Serial Number
Corrosion Protection
This power package is equipped with anodes to help
protect it from galvanic corrosion under moderate
conditions. See the Operator’s Manual for location of
anodes.
Installation Requirements
IMPORTANT: The Jet Drive is considered an
INBOARD engine. The boat it is installed in must
meet industry standards (ABYC, NMMA, etc.),
federal standards and Coast Guard regulations
for INBOARD engine installations
Battery/Battery Cables
IMPORTANT: Boating industry standards (ABYC,
NMMA, etc.), federal standards and Coast Guard
regulations must be adhered to when installing
battery. Be sure battery cable installation meets
the pull test requirements and that positive bat-
tery terminal is properly insulated in accordance
with regulations.
IMPORTANT: Engine electrical system is negative
(–) ground. It is recommended (required in some
states) that battery be installed in an enclosed
case. Refer to regulations for your area.
1. Select a battery that meets all of the following
specifications:
a. 12-volt marine type.
b. 670 Marine Cranking Amps (MCA) or
520 Cold Cranking Amps (CCA) minimum.
c. Reserve capacity rating of at least 100 min-
utes.
2. Select proper size positive (+) and negative (–)
battery cables using chart. Battery should be lo-
cated as close to engine as possible.
IMPORTANT: Terminals must be soldered to
cable ends to ensure good electrical contact. Use
electrical grade (resin flux) solder only. Do not
use acid flux solder, as it may cause corrosion
and a subsequent failure.
Cable Length
Cable Gauge
Up to 1.1 m (3-1/2 ft) 4 (25mm
2
)
1.1 - 1.8 m (3-1/2 - 6 ft) 2 (35mm
2
)
1.8-2.3 m (6 - 7-1/2 ft) 1 (50mm
2
)
2.3-2.9 m (7-1/2 - 9-1/2 ft) 0 (50mm
2
)
2.9-3.7 m (9-1/2 - 12 ft) 00 (70mm
2
)
3.7- 4.6 m (12 - 15 ft) 000 (95mm
2
)
4.6 - 5.8 m (15 - 19 ft)
0000 (120mm
2
)